|
SEQUOIA 512 LCD CVO Shared Service Rev. 12 (2008)
19 Flat panel LCD Monitor with articulating arm Progressive Media & Display II Pkg.
Cardiac/OB/Vascular Calc. Pkg. with High Density Imaging Probe Option
Stress ECHO, Clarify VE, Coronary Flow Reserve, DICOM Store SCU/SR, DICOM Printing
Dual Linear, Extended Trigger, GI Auto Doppler, GI Cadence, Hi Frame Rate DTI, High HR ECG, MIS/MIF
Modality Worklist, Native TEQ, Spectral TEQ, Steered Spatial Compounding,
Signature II, Driving Experience 7 & 8
4V1c (1.5-4.0MHz) Adult Cardiac Sector,
9L4 Vascular/Small Parts Linear,
4C1 (1.5-4.0MHz) Convex
SEQUOIA 512 LCD CVO Rev. 12 (2007)
18 Flat panel LCD Monitor Progressive Media & Display II Pkg.
OB/Vascular Calc. Pkg., DICOM Bulk Store, DICOM Print, Modality Worklist,
Color Doppler, CW/PW Doppler, M-Mode, Angio, Stress Echo, ECG/AUX
Auto GI Doppler, Native TEQ, Spectral TEQ, TEQ, Cadence Cardiac, Cadence GI
Clarify VE, Signature II Options, Driving Experience 7 & 8
4V1c (1.5-4.0MHz) Adult Cardiac Sector,
4C1 (1.5-4.0MHz) Convex,
8L5 (8-5Mhz) Linear
SEQUOIA 512 CVO Cardiac/OB/Vascular/Radiology (Rev. 9.51) 2004
NTHI -Tissue Harmonics, Driving Experience 7 & 8, TEQ, Spectral TEQ,
DICOM Store/Print, DICOM Modality Worklist, Freestyle, Freestyle Compounding,
MOD, Color Doppler, CW/PW Doppler, M-Mode, Angio, Speckle Reduction, Steered Spatial Compounding,
Signature II Package, GI Auto Doppler,
4V1c (4-1Mhz) Cardiac,
8L5 (8-5Mhz) Linear,
4C1 (4-1Mhz) Convex
SEQUOIA 512 CVO (REV. 9.51) 2003
NTHI -Tissue Harmonics, Driving Experience 7 & 8, OB, Vascular
DICOM Store/Print, DICOM Modality Worklist, Stress Echo, Signature II option
TEQ, MOD, Color Doppler, CW/PW Doppler, M-Mode, Angio, ECG/AUX
4V1c (4-1Mhz) Cardiac,
8L5 (8-5Mhz) Linear,
4C1 (4-1Mhz) Convex
SEQUOIA 512 CVO Shared Service Rev. 9.51
NTHI -Tissue Harmonics, TEQ Tissue Equalization, Driving Experience 7 & 8
DICOM Store/Print, MOD, STRESS ECHO, Color Doppler, CW/PW Doppler
M-Mode, Angio, ECG/AUX, B-Color
3V2c (2-3MHz) Cardiac Sector,
8L5 (8-5MHz) Linear,
4C1 (1.5-4.0MHz) Convex
SEQUOIA 512 CVO Shared Service Rev. 9.51
NTHI -Tissue Harmonics, Driving Experience 7, Dicom Store
STRESS ECHO, MOD, Color Doppler, CW/PW Doppler, DTI
M-Mode, Angio, ECG/AUX, Third Party Enabled, B-Color
3V2c (2-3MHz) Cardiac Sector,
8L5 (8-5MHz) Linear,
4C1 (1.5-4.0MHz) Convex
SEQUOIA C512 C/V (REV. 9.51) 2003
Color Doppler, CW/PW Doppler, M-Mode, Angio, Stress Echo, ECG/AUX
CPS Cardiology, CPS General Imaging, Card Cadence 2, Color Freestyle, Dicom Store,
Driving Experience 7 & 8, Signature II option, Freestyle, Modality Worklist, Native TEQ, Spectral TEQ, TEQ, NTHI-Tissue Harmonics
4V1c (4-1Mhz) Cardiac,
6L3 (6-3Mhz) Vascular Linear
SEQUOIA C512 (REV. 9.51) 2005
Color Doppler, CW/PW Doppler, M-Mode, Angio, Stress Echo, CPS Cardiology, ECG/AUX
CPS General Imaging, Cadence Trig Burst, Card cadence 2, Dicom Store, Driving Experience 7 & 8
Modality WorkList, NTHI-Tissue Harmonics, TEQ, Signature II option
4V1c (4-1Mhz) Cardiac
SEQUOIA 512 GI -OB/Vascular/Radiology (Rev. 9.51) 2004
NTHI -Tissue Harmonics, Driving Experience 7 & 8, TEQ, Spectral TEQ,
DICOM Store/Print, DICOM Modality Worklist, Freestyle, Freestyle Compounding,
MOD, Color Doppler, PW Doppler, M-Mode, Angio, Speckle Reduction, Steered Spatial Compounding,
Signature II Package, GI Auto Doppler,
15L8w (15-8Mhz) Linear,
4C1 (4-1Mhz) Convex,
EV8C4 (8-4Mhz) Endovaginal
SEQUOIA 512 GI -OB/Vascular/Radiology (Rev. 9.51)
NTHI -Tissue Harmonics, Driving Experience 7 & 8
DICOM Store/Print, DICOM Modality Worklist
MOD, Color Doppler, PW Doppler, M-Mode, Angio
4C1 (6-2MHz) Convex,
8L5 (5-8MHz) Linear
SEQUOIA 512 GI -OB/Vascular/Radiology (Rev. 9.51)
NTHI -Tissue Harmonics, Driving Experience 7
DICOM Store/Print, DICOM Modality Worklist
MOD, Color Doppler, PW Doppler, M-Mode, Angio
4C1 (6-2MHz) Convex,
8L5 (5-8MHz) Linear
SEQUOIA 512 CVO Shared Service Rev. 9.51 PAL/220V/50Hz (2005/2006 Software Version)
NTHI -Tissue Harmonics, 3rd Party Service Enabled, TEQ Tissue Equalization
DICOM Store/Print, DICOM Modality Worklist, MOD, STRESS ECHO, Signature II Option
Color Doppler, CW/PW Doppler, M-Mode, Angio, ECG/AUX, B-Color, Spatial Compounding
3V2c (2-3MHz) Cardiac Sector,
8L5 (8-5MHz) Linear,
4C1 (1.5-4.0MHz) Convex
SEQUOIA C256 Cardiac (Rev. 9.5)
NTHI -Tissue Harmonics, Spectral TEQ, TEQ, Driving Experience 7 & 8,
STRESS ECHO, MOD, Color Doppler, CW/PW Doppler,
M-Mode, Angio, ECG/AUX,
3V2c Adult Cardiac Sector
SEQUOIA C256 Cardiac (Rev. 9.5)
NTHI -Tissue Harmonics , Modality Work list, Driving Experience 7 & 8,
Dicom Store / Print, STRESS ECHO, MOD, Color Doppler, CW/PW Doppler,
M-Mode, Angio, ECG/AUX,
3V2c Adult Cardiac Sector
SEQUOIA C256 Cardiac (Rev. 9.5)
NTHI -Tissue Harmonics , Modality Work list, Driving Experience 7 & 8,
Dicom Store, STRESS ECHO, MOD, Color Doppler, CW/PW Doppler,
M-Mode, Angio, ECG/AUX,
3V2c Adult Cardiac Sector
SEQUOIA C256 Cardiac (Rev. 9.5)
NTHI -Tissue Harmonics, Cardiac Cadence 2, Driving Experience 7,
STRESS ECHO, MOD, Color Doppler, CW/PW Doppler, Dicom Store
M-Mode, Angio, ECG/AUX,
3V2c Adult Cardiac Sector
SEQUOIA C256 Cardiac (Rev. 9.5)
NTHI -Tissue Harmonics, Driving Experience 7,
STRESS ECHO, MOD, Color Doppler, CW/PW Doppler,
M-Mode, Angio, ECG/AUX,
3V2c Adult Cardiac Sector
SEQUOIA C256 Cardiac/Vascular (Rev. 9.5)
NTHI -Tissue Harmonics, DTI, Driving Experience 7, Cadence
STRESS ECHO, MOD, Color Doppler, CW/PW Doppler,
M-Mode, Angio, ECG/AUX,
3V2c Adult Cardiac Sector,
8L5 Vascular Linear
SEQUOIA C256 Cardiac/Vascular (Rev. 9.5)
Driving Experience 7 & 8, Calc data to MO
STRESS ECHO, MOD, Color Doppler, CW/PW Doppler,
M-Mode, Angio, ECG/AUX,
3V2c Adult Cardiac Sector,
6L3 Vascular Linear
|